2008-04-23 | System reference codes (B3xx)
标签:iseries src connection monitoring b2xx 参考代码
These error codes indicate a problem in the connection monitoring between the Hardware Management Console and a partition that is running on the managed system. The HMC posts these error codes into the error log in Service Focal Point but does not report them to the operating systems running on the managed system.
Use the following links to display the appropriate B3xx reference code table:
| Reference Code | Description/Action Perform all actions before exchanging Failing Items | Failing Item |
|---|---|---|
| B3010001 | Hardware Management Console (HMC) or partition connection monitoring fault | NEXTLVL |
| B3010002 |
HMC or partition connection monitoring fault Perform the following steps:
|
PTNNTWK |
| B3010004 |
HMC or partition connection monitoring fault |
NEXTLVL |
| B3010012, B3010013, B3010019, B3010020, B3010023, B3010025, B3010026 | HMC or partition connection monitoring fault | NEXTLVL |
| B3010027 |
HMC or partition connection monitoring fault Before using the entry in the Failing Items column, do the following:
|
NEXTLVL |
| B3010029, B301002B, B301002C, B301002D | HMC or partition connection monitoring fault | NEXTLVL |
| Reference Code | Description/Action Perform all actions before exchanging Failing Items | Failing Item |
|---|---|---|
| B3020001 |
Hardware Management Console (HMC) or partition connection monitoring fault Before using the entry in the Failing Items column, do the following:
|
NEXTLVL |
| Reference Code | Description/Action Perform all actions before exchanging Failing Items | Failing Item |
|---|---|---|
| B3030001 | The communication link between the service processor and the Hardware Management Console (HMC) failed.
Note:
This error might be a temporary condition caused by either the HMC or the system that the HMC is connected, being shutdown, restarted, upgraded or other intermittent conditions. While attempts are made to only report these errors when a connection has been lost. It is important to follow the procedures in the symbolic FRU list to determine if there is still a connection problem and how to resolve the issue.
|
|
| B3030002 | A single partition HMC link failed.
Note:
This error might be a temporary condition caused by either the HMC or the system that the HMC is connected, being shutdown, restarted, upgraded or other intermittent conditions. While attempts are made to only report these errors when a connection has been lost. It is important to follow the procedures in the symbolic FRU list to determine if there is still a connection problem and how to resolve the issue.
|
|
| B3030003 | Multiple partition HMC links failed.
Note:
This error might be a temporary condition caused by either the HMC or the system that the HMC is connected, being shutdown, restarted, upgraded or other intermittent conditions. While attempts are made to only report these errors when a connection has been lost. It is important to follow the procedures in the symbolic FRU list to determine if there is still a connection problem and how to resolve the issue.
|
|
| B3030004 | All partition links for a single system to HMC failed.
Note:
This error might be a temporary condition caused by either the HMC or the system that the HMC is connected, being shutdown, restarted, upgraded or other intermittent conditions. While attempts are made to only report these errors when a connection has been lost. It is important to follow the procedures in the symbolic FRU list to determine if there is still a connection problem and how to resolve the issue.
|
|
| B3030005 | All system links from one system to a single HMC failed.
Note:
This error might be a temporary condition caused by either the HMC or the system that the HMC is connected, being shutdown, restarted, upgraded or other intermittent conditions. While attempts are made to only report these errors when a connection has been lost. It is important to follow the procedures in the symbolic FRU list to determine if there is still a connection problem and how to resolve the issue.
|
|
| B3030006 | The links between a single HMC and a single managed system failed.
Note:
This error might be a temporary condition caused by either the HMC or the system that the HMC is connected, being shutdown, restarted, upgraded or other intermittent conditions. While attempts are made to only report these errors when a connection has been lost. It is important to follow the procedures in the symbolic FRU list to determine if there is still a connection problem and how to resolve the issue.
|
|
| B3030007 | A single HMC link to more than one managed system occurred.
Note:
This error might be a temporary condition caused by either the HMC or the system that the HMC is connected, being shutdown, restarted, upgraded or other intermittent conditions. While attempts are made to only report these errors when a connection has been lost. It is important to follow the procedures in the symbolic FRU list to determine if there is still a connection problem and how to resolve the issue.
|
|
| B3030008 | One HMC link to another single HMC failed.
Note:
This error might be a temporary condition caused by either the HMC or the system that the HMC is connected, being shutdown, restarted, upgraded or other intermittent conditions. While attempts are made to only report these errors when a connection has been lost. It is important to follow the procedures in the symbolic FRU list to determine if there is still a connection problem and how to resolve the issue.
|
|
| B3030009 | One HMC link to more than one HMC occurred.
Note:
This error might be a temporary condition caused by either the HMC or the system that the HMC is connected, being shutdown, restarted, upgraded or other intermittent conditions. While attempts are made to only report these errors when a connection has been lost. It is important to follow the procedures in the symbolic FRU list to determine if there is still a connection problem and how to resolve the issue.
|
|
| B303000A | The HMC lost links to all managed systems.
Note:
This error might be a temporary condition caused by either the HMC or the system that the HMC is connected, being shutdown, restarted, upgraded or other intermittent conditions. While attempts are made to only report these errors when a connection has been lost. It is important to follow the procedures in the symbolic FRU list to determine if there is still a connection problem and how to resolve the issue.
|
|
| B303000B | Multiple HMCs lost links to a single managed system.
Note:
This error might be a temporary condition caused by either the HMC or the system that the HMC is connected, being shutdown, restarted, upgraded or other intermittent conditions. While attempts are made to only report these errors when a connection has been lost. It is important to follow the procedures in the symbolic FRU list to determine if there is still a connection problem and how to resolve the issue.
|
|
| B303000C | Multiple HMCs lost links to multiple managed systems.
Note:
This error might be a temporary condition caused by either the HMC or the system that the HMC is connected, being shutdown, restarted, upgraded or other intermittent conditions. While attempts are made to only report these errors when a connection has been lost. It is important to follow the procedures in the symbolic FRU list to determine if there is still a connection problem and how to resolve the issue.
|
|
| B303000D | Multiple HMCs lost links to multiple managed systems.
Note:
This error might be a temporary condition caused by either the HMC or the system that the HMC is connected, being shutdown, restarted, upgraded or other intermittent conditions. While attempts are made to only report these errors when a connection has been lost. It is important to follow the procedures in the symbolic FRU list to determine if there is still a connection problem and how to resolve the issue.
|
|
| B303000E | The Network Interface Card (NIC) failed
Use the error codes offered in the HMC Focal Point to diagnose and repair the problem. For more information, see Using Service Focal Point. Note:
This error might be a temporary condition caused by either the HMC or the system that the HMC is connected, being shutdown, restarted, upgraded or other intermittent conditions. While attempts are made to only report these errors when a connection has been lost. It is important to follow the procedures in the symbolic FRU list to determine if there is still a connection problem and how to resolve the issue.
|
SYSNTWK |
| B303000F | A single partition HMC link failure occurred on a redundant path.
Note:
This error might be a temporary condition caused by either the HMC or the system that the HMC is connected, being shutdown, restarted, upgraded or other intermittent conditions. While attempts are made to only report these errors when a connection has been lost. It is important to follow the procedures in the symbolic FRU list to determine if there is still a connection problem and how to resolve the issue.
|
|
| B3030010 | A single HMC link to one HMC failure occurred on a redundant path.
Note:
This error might be a temporary condition caused by either the HMC or the system that the HMC is connected, being shutdown, restarted, upgraded or other intermittent conditions. While attempts are made to only report these errors when a connection has been lost. It is important to follow the procedures in the symbolic FRU list to determine if there is still a connection problem and how to resolve the issue.
|
|
| B3030011 | Server firmware connection monitoring to the flexible service processor failed.
Note:
This error might be a temporary condition caused by either the HMC or the system that the HMC is connected, being shutdown, restarted, upgraded or other intermittent conditions. While attempts are made to only report these errors when a connection has been lost. It is important to follow the procedures in the symbolic FRU list to determine if there is still a connection problem and how to resolve the issue.
|
|
| B3030012 | Flexible service processor connection monitoring of server firmware failed.
Note:
This error might be a temporary condition caused by either the HMC or the system that the HMC is connected, being shutdown, restarted, upgraded or other intermittent conditions. While attempts are made to only report these errors when a connection has been lost. It is important to follow the procedures in the symbolic FRU list to determine if there is still a connection problem and how to resolve the issue.
|
|
| B3030013 | The communication path (mailbox) between server firmware and the flexible service processor failed.
Note:
This error might be a temporary condition caused by either the HMC or the system that the HMC is connected, being shutdown, restarted, upgraded or other intermittent conditions. While attempts are made to only report these errors when a connection has been lost. It is important to follow the procedures in the symbolic FRU list to determine if there is still a connection problem and how to resolve the issue.
|
|
| B3031000 | Customer reported a console problem when creating a serviceable event on the HMC user interface.
Contact the customer for more information about the problem. |
|
| B3031001 | Customer reported a power problem when creating a serviceable event on the HMC user interface.
Contact the customer for more information about the problem. |
|
| B3031002 | Customer reported a processor problem when creating a serviceable event on the HMC user interface.
Contact the customer for more information about the problem. |
|
| B3031003 | Customer reported a LAN problem when creating a serviceable event on the HMC user interface.
Contact the customer for more information about the problem. |
|
| B3031004 | Customer reported a software problem when creating a serviceable event on the HMC user interface.
Contact the customer for more information about the problem. |
|
| B3031005 | Customer reported a input/output (I/O) problem when creating a serviceable event on the HMC user interface.
Contact the customer for more information about the problem. |
|
| B3031006 | Customer reported a problem when creating a serviceable event on the HMC user interface.
Contact the customer for more information about the problem. |
|
| B3031007 | Customer tested problem reporting by creating a serviceable event on the HMC user interface.
Contact the customer for more information about the problem. |
|
| B3031100 | Customer reported a problem when creating a serviceable event on the HMC user interface.
Contact the customer for more information about the problem. |
|
| B3031101 | Customer reported a power problem when creating a serviceable event on the HMC user interface.
Contact the customer for more information about the problem. |
|
| B3031102 | Customer reported a processor problem when creating a serviceable event on the HMC user interface.
Contact the customer for more information about the problem. |
|
| B3031103 | Customer reported a LAN problem when creating a serviceable event on the HMC user interface.
Contact the customer for more information about the problem. |
|
| B3031104 | Customer reported a software problem when creating a serviceable event on the HMC user interface.
Contact the customer for more information about the problem. |
|
| B3031105 | Customer reported a input/output (I/O) problem when creating a serviceable event on the HMC user interface.
Contact the customer for more information about the problem. |
|
| B3031106 | Customer reported a problem when creating a serviceable event on the HMC user interface.
Contact the customer for more information about the problem. |
|
| B3031107 | Customer tested problem reporting by creating a serviceable event on the HMC user interface.
Contact the customer for more information about the problem. |
|
| B3036600 | The HMC failed to retrieve a dump from a managed system. If you have a redundant HMC environment, a peer HMC might have retrieved the dump. This might be a temporary problem.
After receiving this error, perform the following steps:
|
|
| B3036601 | The HMC failed to retrieve a platform system dump from the managed system. If you have a redundant HMC environment, a peer HMC might have retrieved the dump. This might be a temporary problem.
After receiving this error, perform the following steps:
|
|
| B3036602 | The HMC failed to retrieve a dump from the service processor. If you have a redundant HMC environment, a peer HMC might have retrieved the dump. This might be a temporary problem. This might be a temporary problem.
After receiving this error, perform the following steps:
|
|
| B3036604 | The HMC failed to retrieve a power subsystem dump from the managed system. If you have a redundant HMC environment, a peer HMC might have retrieved the dump. This might be a temporary problem.
After receiving this error, perform the following steps:
|
|
| B3036620 | Primary HMC arbitration failure for domain {0} with peers {1}.
Note:
Domain indicates which domain the managed system belongs to. Peers indicate what HMC are also connected to the service processor.
This error code indicates that this HMC did receive primary information from a peer HMC. To resolve this issue ensure that there is connectivity to the FSP and the other HMC connected to the managed system. |
|
| B3036625 | Primary HMC arbitration failure for domain {0} with peers {1}.
Note:
Domain indicates which domain the managed system belongs to. Peers indicate what HMC are also connected to the service processor.
This error code indicates that this HMC could not communicate with the service processor to either set itself as a primary or to determine if other HMCs are connected. To resolve this issue ensure that there is connectivity to the service processor and the other HMC connected to the managed system. |
| Reference Code | Description/Action Perform all actions before exchanging Failing Items | Failing Item |
|---|---|---|
| B3100500, B3112420 | Ethernet network failure
Do the following:
|
NEXTLVL |